SCIFIT SXT7000 User Manual Page 48

  • Download
  • Add to my manuals
  • Print
  • Page
    / 65
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 47
48
2. Pull the contact heart rate cable out of the upright until you can access the
two (2) connection points on the ski pole cables (P2773).
3. Pull each male-to-female connection apart in the middle of the ski pole
cables.
4. Insert the head of a small flathead screwdriver between the black plastic
grip and contact grip end cap. Pry the end cap off and set aside.
5. Insert the head of the screwdriver under the corner of each silver plate
and pry away from the black plastic grip. Note: There are cables
connected to each plate.
6. Disconnect the ski pole cable (P2773) from the silver contact plate. Do
not let the cables fall inside the ski poles.
7. Using a small Philips screwdriver, remove the two (2) screws that run
through the center of each black plastic grip. Do not lose the nuts that
are on the opposite side of the black plastic grip as the screw heads.
8. Remove the black plastic grips.
9. Tape the two (2) female ends on the new cable, which connect to the
silver contact plate, to the male-to-female connections on the end of the
old ski pole cable.
10. Pull the old cable out the top of the ski pole while guiding the other end
through the contact heart rate cable hole in the ski pole.
11. Remove the tape when the two (2) female connections on the new cable
come out the top of the ski pole.
12. Insert one (1) of the female connections through the top ½” hole on one
(1) side of the top of the ski pole. Insert the other female connection
through the bottom hole on the opposite side of the same ski pole. See
diagram below.
13. Insert each cable through the black plastic grips.
14. Reposition black plastic grips and reinstall the screws and nuts in each.
Be careful not to over-tighten the screws as this will cause the black
plastic grip to break.
15. Reconnect the ski pole cable to each silver contact plate.
16. Insert silver plate back into the channel in the black plastic grip. Make
sure not to pinch the cables under the silver contact plate.
17. Install the contact grip end cap.
18. Test the unit in different programs to verify operation. Do not use the
Heart Rate program as it requires the use of a wireless chest strap.
Page view 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 64 65

Comments to this Manuals