O. Contact Grip Replacement SX, SXT
1. Insert the head of a small flathead screwdriver between the black plastic
grip and contact grip end cap. Pry the end cap off and set aside.
2. Insert the head of the screwdriver under the corner of each silver plate
and pry away from the black plastic grip. Note: There are cables
connected to each plate.
3. Disconnect the contact grip cable from each silver contact plate on the
SX’s. Disconnect the ski pole cable (P1927 or P2773) from the silver
contact plate on the SXT’s. Do not let the cables fall inside the
handlebars on the SX’s or the ski poles on the SXT’s.
4. Using a small Philips screwdriver, remove the two (2) screws that run
through the center of each black plastic grip. Do not lose the nuts that
are on the opposite side of the black plastic grip as the screw heads.
5. Remove the black plastic grips.
6. Position new black plastic grips and reinstall the screws and nuts in each.
Be careful not to over-tighten the screws as this will cause the black
plastic grip to break.
7. Reconnect the contact grip cable or ski pole cable to each silver contact
plate. Note: The cable with the white stripe connects to the silver
plate that makes contact with the palm.
8. Insert silver plate back into the channel in the black plastic grip. Make
sure not to pinch the cables under the silver contact plate.
9. Install the contact grip end cap.
10. Test the unit in different programs to verify operation. Do not use the
Heart Rate program as it requires the use of a wireless chest strap.