Plug the wireless heart rate PCB back into the upper PCB. It plugs
into the bottom 3-pin header on the right side of the upper PCB (as
shown above).
The ribbon cable plugs into the bottom ribbon cable header on the
right side of the upper PCB.
If your unit has Broadcast Vision, Cardio Theater, etc., the cable
connects to the 8-pin, +8VDC power header. When looking at the
upper PCB from the front, this header is located on the lower right
backside corner of the upper PCB (as shown above).
7. Reinsert the upper PCB assembly into the front of the console.
8. Reinstall the two (2), outer countersunk screws in the back of the plastic
console.
9. Place the console assembly back onto the mounting plate and install the
four (4) display mounting screws.
10. The model of machine must be defined. (You must rotate the cranks to
power up the upper display to perform this next procedure.) When the
display lights up, see if “UNDEFINED” appears in the top window. If
UNDEFINED” appears, press the UP arrow one time to display “PRO” or
“PRO 2”. Once “PRO” or “PRO 2” is displayed, press ENTER to save. If
no unit type appears in the top window upon power up, the display has
probably been preset at the factory. To verify this, hold the SCAN,
SELECT, and PAUSE for three seconds until “FACTORY SETTINGS
appears, then release. Do not continue to hold keys once this
appears. Press ENTER once. If “PRO” or “PRO 2” appears in the top
window, press ENTER eight (8) times until “UPDATING” appears. If
PRO” or “PRO 2” doesn’t appear in the top window, press and hold
SELECT and the UP or DOWN arrow simultaneously until “PRO” or “PRO
2” does appears.
11. Verify operations of the unit by using different programs.