V. Adjustments and Parts Replacement
A. Upper (Display) PCB Replacement (Use this procedure for
PROII’s thru 650-005503.)
1. Using a Philips screwdriver, remove the four (4) display mounting screws
on the back of the display mounting plate.
2. Disconnect all cables running to the upper PCB (P1558) and remove the
upper console assembly from the unit. Make sure the cables do not fall
into the neck of the unit.
3. Remove the two (2) outer countersunk screws in the back of the plastic
console (A1537), using a Philips screwdriver. This will free the upper PCB
and overlay (P1560) from the plastic console. Do not touch any
components on the PCB. Touching components could cause static
damage. If the wireless heart rate receiver is still plugged into the upper
PCB, unplug it now.
4. Remove the six (6) standoffs from the upper PCB. This may require the
use of a 5/16” nut driver or socket. The upper PCB will separate from the
overlay.