IV. Electrical Troubleshooting
A. Electrical Troubleshooting Table
Problem Possible Reason Solution
No lights are showing on the
upper PCB at idle.
Unit is not in use.
Start rotating cranks (at least
13 RPMs). Unit stays lit for 15
seconds after use unless a wall
pack is in use.
No lights on upper PCB when
unit is pedaled.
Faulty lower PCB.
Faulty upper PCB.
Bad Telco or ribbon cable
connection.
Brake is shorted to the frame.
See flowchart.
See flowchart.
See flowchart.
See flowchart.
Lights on upper PCB are dim.
Faulty lower PCB. Replace lower PCB.
Lights on upper PCB are
frozen.
Faulty upper PCB. Replace upper PCB.
Lights on upper PCB flicker
and then go dead.
Bad Telco or ribbon cable
connection.
Faulty lower PCB.
Faulty upper PCB.
Fix connection or replace
cable.
Replace lower PCB.
Replace upper PCB.
Lights on upper PCB go out
as soon as you stop pedaling
or go to change direction.
Battery is weak.
Bad brake to lower PCB
connection.
Charge battery with wall pack.
If problem continues, replace
battery.
Fix connection.
“PAUSED” is displayed in
top display window.
The PAUSE/CLEAR button has
been pressed during program.
Press START to resume
program or PAUSE/CLEAR to
return to start up screen.
Display resets after starting
program.
Bad Telco or ribbon cable
connection.
13 RPMs not maintained.
Faulty upper PCB.
Fix connection or replace
cable.
Maintain 13+ RPMs to keep the
upper PCB lit.
Replace upper PCB.
Page view 11